IDS X64 Installer Manual 700-398-02D Issued August 2010
51
LOCATIONS 211 - 218
Partition Arm Options (Partitions 1 8)
These locations are used to configure arm options for each partition. Refer to Table 25 for the
values that can be selected.
Each location represents a partition:
Location 211 is partition 1
Location 212 is partition 2
Location 213 is partition 3
Location 214 is partition 4
Location 215 is partition 5
Location 216 is partition 6
Location 217 is partition 7
Location 218 is partition 8
(This is an advanced location).
Quick Arm:
This option allows the user to arm the panel by holding down the [1] key for three seconds. The keypad
will beep once to indicate that the arm sequence has begun.
Force Arm:
With this option enabled, the panel will arm with violated zones e.g. an open window. This forces any
violated zones to be temporarily bypassed when the panel arms. If such bypassed zones restore during
the arm cycle (the window is closed, for example), the zone is automatically re-activated (un-bypassed)
and a subsequent violation will trigger an alarm.
Siren Toot on Away Arm / Disarm:
This option allows the user an audible confirmation that arming or disarming of the panel has occurred.
The siren is programmed to give a short beep after successful arming, and two short beeps after
disarming. This is useful when used in conjunction with remote or key-switch arming/disarming.
Engineer Reset:
Enabling this option will prevent the panel from being rearmed after an alarm condition has occurred. In
order to re-arm the panel, the installer will be required to enter a valid installer code.
If option 7 is set in location 16, an engineer reset trouble condition will also be displayed on the keypad.