Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
Table 11: Number of Digits Data
[INSTALLER CODE] [*] [2] [3] [*] [NUMBER OF DIGITS] [*]
The valid data range is either 4 or 6.
Number of Account Code Digits (default = 4)
This location sets the account code length to either 4 or 6 digits. If the length of your account
codes is 4 digits and then they are changed to 6 digits, the last two digits will be set to 0.
[INSTALLER CODE] [*] [2] [4] [*] [NUMBER OF DIGITS] [*]
The valid data range is: 4 or 6.
9.3 Daylight Savings
Month to Start Daylight Saving (default = 1)
Select the month for Daylight Saving to commence, as per Table 12.
Table 12: Month Data
[INSTALLER CODE] [*] [2] [5] [*] [MONTH] [*]
The valid data range: 1 – 12, with 0 to disable.
NOTE:
If this location is disabled, then by default, locations 26 and 27 will also be disabled. This means that