Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
Keypad Panic Reporting Code
This location is configured per partition. This 2-digit code is reported when the [P] key on any keypad
belonging to the specified partition is held down for two seconds. Option 2 in Table 45 needs to be
enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [3] [3] [7] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
The valid data range is: 01-FF, with 00 to disable.
If any of the sub-locations are disabled here, then the reporting codes will not report – even if they are
enabled at 9.16 Event Reporting Options - Advanced.
Partition no. is: 1-8.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
NOTE:
The values are hexadecimal. Refer to Table 3 on how to program hexadecimal values.
The 2-digit fire code is reported when the [F] key on any keypad belonging to the specified partition is
held down for two seconds. Option 3 in Table 45 needs to be enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [3] [3] [8] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
The valid data range is: 01-FF, with 00 to disable.
If any of the sub-locations are disabled here, then the reporting codes will not report – even if they are
enabled at 9.16 Event Reporting Options - Advanced.
Partition no. is: 1-8.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
NOTE:
The values are hexadecimal. Refer to Table 3 on how to program hexadecimal values.
The 2-digit medical code is reported when the [M] key on any keypad belonging to the specified partition
is held down for two seconds. Option 4 in Table 45 needs to be enabled.
Enter a 2-digit reporting code for each of the 8 partitions and program as a 16-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [3] [3] [9] [*] [PARTITION NO.] [*] [REPORTING CODE] [*]
The valid data range is: 01-FF, with 00 to disable.