EasyManua.ls Logo

IMO HD2-3.7A-43 - Page 163

IMO HD2-3.7A-43
408 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HD2 Series Inverter Function Parameter List
-154-
Function
code
Name
Description
Default
value
Modify
of static friction
P03.30
High speed
friction
compensation
coefficient
0.0–100.0%
0.0%
○
P03.31
Corresponding
frequency of
high-speed
friction torque
P03.29–400.00Hz
50.00Hz
○
P03.32
Enabling torque
control
0: Disable
1: Enable
0
◎
P03.33
Flux weakening
integral gain
0–8000
1200
○
P03.34
Flux-weakening
control mode
0x000–0x112
Ones place: Control mode
0: Mode 0
1: Mode 1
2: Mode 2
Tens place: Compensation of inductance
saturation coefficient
0: Enable
1: Disable
Hundreds place: Reserved
0: Reserved
1: Reserved
0x000
○
P03.35
Control
optimization
setting
0x0000–0x1111
Ones place: Torque command selection
0: Torque reference
1: Torque current reference
Tens place: Reserved
0: Reserved
1: Reserved
Hundreds place: Whether to enable ASR integral
separation
0: Disable
1: Enable
Thousands place: Reserved
0: Reserved
0x0000
○

Table of Contents