HD2 Series Inverter Function Parameter List
-154-
Function
code
Name
Description
Default
value
Modify
of static friction
P03.30
High speed
friction
compensation
coefficient
0.0–100.0%
0.0%
P03.31
Corresponding
frequency of
high-speed
friction torque
P03.29–400.00Hz
50.00Hz
P03.32
Enabling torque
control
0: Disable
1: Enable
0
P03.33
Flux weakening
integral gain
08000
1200
P03.34
Flux-weakening
control mode
0x000–0x112
Ones place: Control mode
0: Mode 0
1: Mode 1
2: Mode 2
Tens place: Compensation of inductance
saturation coefficient
0: Enable
1: Disable
Hundreds place: Reserved
0: Reserved
1: Reserved
0x000
P03.35
Control
optimization
setting
0x00000x1111
Ones place: Torque command selection
0: Torque reference
1: Torque current reference
Tens place: Reserved
0: Reserved
1: Reserved
Hundreds place: Whether to enable ASR integral
separation
0: Disable
1: Enable
Thousands place: Reserved
0: Reserved
0x0000