The related function code is set in the following table.
Function 
Code
Parameter 
Name
Setting Range Unit Default
Effective 
Time
Property
Control 
Mode
H09 02
Working mode 
of self-adaptive 
notch
0–4
0: Self-adaptive notch 
not updated
1: Only one notch (3rd 
notch) valid
2: Both notches (3rd 
and 4th notches) valid
3: Only detect 
resonance frequency 
(displayed in H09-24), 
not update parameters
4: Restore parameters 
to default setting
- 0 Immediate
During 
running
PST
H09  12 
1st notch 
frequency
50–4000 Hz 4000 Immediate
During 
running
PS
H09  13 
1st notch width 
level
0–20 - 2 Immediate
During 
running
PS
H09  14 
1st notch depth 
level
0–99 - 0 Immediate
During 
running
PS
H09  15 
2nd notch 
frequency
50–4000 Hz 4000 Immediate
During 
running
PS
H09  16 
2nd notch width 
level
0–20  - 2 Immediate
During 
running
PS
H09  17 
2nd notch depth 
level
0–99 - 0 Immediate
During 
running
PS
H09 18
3rd notch 
frequency
50–4000 Hz Hz 4000 Immediate
During 
running
PS
H09 19
3rd notch width 
level
0–20 - 2 Immediate
During 
running
PS
H09 20
3rd notch depth 
level
0–99 - 0 Immediate
During 
running
PS
H09 21
4th notch 
frequency
50–4000 Hz 4000  Immediate
During 
running
PS
H09 22
4th notch width 
level
0–20 - 2 Immediate
During 
running
PS
H09 23
4th notch depth 
level
0–99 - 0 Immediate
During 
running
PS
H09 24
Obtained 
resonance 
frequency
0–2 Hz 0 -
At 
display
PS