Group H0D: Auxiliary Function Parameters
Function
Code
Parameter Name Setting Range Unit Default
Effective
Time
Property
Control
Mode
H0D 00 Software reset
0: No operation
1: Enabled
- 0 Immediate At stop -
H0D 01 Fault reset
0: No operation
1: Enabled
- 0 Immediate At stop -
H0D 02
Ofine load inertia
auto-tuning
- - - Immediate
During
running
-
H0D 03
Initial angle auto-
tuning
0: No operation
1: Enabled
- 0 Immediate At stop -
H0D 05 Emergency stop
0: No operation
1: Enabled
- 0 Immediate
During
running
-
H0D 10
Analog automatic
adjustment
0: No operation
1: AI1 adjustment
2: AI2 adjustment
- 0 Immediate At stop -
H0D 11 Jog function - - - - - -
H0D 17
DI/DO forced
input and output
enabled
0: No operation
1: Simulated DI
enabled, simulated
DO disabled
2: Simulated DO
enabled, simulated
DI disabled
3: Simulated DI and
DO enabled
- 0 Immediate
During
running
-
H0D 18
DI forced input
setting
0–0x01FF - 0x01FF Immediate
During
running
-
H0D 19
DO forced output
setting
0–0x001F - 0 Immediate
During
running
-