EasyManua.ls Logo

Inovance IS620P Series - Cable Towline; If Cable Towline Is Used; Precautions of Using Cables

Inovance IS620P Series
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3 Wiring of Servo System IS620P User Manual
- 72 -
3.7 Precautions of Using Cables
1. Do not bend or apply tensions to cables. The core wire of a signal cable is only 0.2 or 0.3
mm thin. Handle the cables carefully.
2. In scenarios where cables need to be moved, use exible cables. Common cables are
easily damaged after being bent for a long time. Cables of low power servo motors cannot
be moved.
3. If cable towline is used, make sure:
The bending radius of the cable must be at least 10 times of the diameter of the cable.
Do not x or bundle the cables inside the cable towline. You can bundle them at both ends
of the cable towline.
Cables must not be wound or warped.
Space factor inside the cable towline must not exceed 60%.
Do not mix cables of great difference in size together. Otherwise, thick cables may crush
thin cables. If you need to use them together, place a spacer plate to separate them.
Figure 3-22 Cable towline
Cable end
Cable towline
Cable

Table of Contents

Other manuals for Inovance IS620P Series

Related product manuals