Chapter 6 Troubleshooting IS620P User Manual
- 124 -
d. No.2 resettable alarm
Display Alarm Name Fault Type Resettable
DO Outputs
AL3 AL2 AL1
Er.110
Setting error of frequency-
division pulse output
NO.3 Yes 1 1 1
Er.601 Home return timeout NO.3 Yes 0 0 0
Er.831 AI zero drift too large NO.3 Yes 1 1 1
Er.900 DI emergency braking NO.3 Yes 1 1 1
Er.909 Motor overload NO.3 Yes 1 1 0
Er.920 Regen resistor overload NO.3 Yes 1 0 1
Er.922
The external regen resistor too
small
NO.3 Yes 1 0 1
Er.939 Motor power cable breaking NO.3 Yes 1 0 0
Er.941
Parameter modication taking
effect only after re-power-on
NO.3 Yes 0 1 1
Er.942
Parameter storage too
frequent
NO.3 Yes 0 1 1
Er.950 Forward overtravel NO.3 Yes 0 0 0
Er.952 Reverse overtravel NO.3 Yes 0 0 0
Er.980 Encoder internal fault NO.3 Yes 0 0 1
Er.990 Power input phase loss NO.3 Yes 0 0 1
Er.994 CAN address conict NO.3 Yes 0 0 1
Er.A40 Motor auto-tuning failure NO.3 Yes 0 1 0

Table of Contents

Other manuals for Inovance IS620P Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS620P Series and is the answer not in the manual?

Inovance IS620P Series Specifications

General IconGeneral
BrandInovance
ModelIS620P Series
CategoryServo Drives
LanguageEnglish

Related product manuals