IS620P User Manual                                                                                     Chapter 7 Function Code Table
- 193 -
Function 
Code
Parameter Name Setting Range Unit Default
Effective 
Time
Property
Control 
Mode
H11 14
Maximum 
running speed of 
1st displacement
1–6000 rpm 200 Immediate
During 
running
P
H11 15
Acceleration/
Deceleration 
time of 1st 
displacement
0–65535 ms (s) 10 Immediate
During 
running
P
H11 16
Waiting time 
after 1st 
displacement
0–10000 ms (s) 10 Immediate
During 
running
P
H11 17
2nd 
displacement
-1073741824 
to 1073741824
Reference 
unit
10000  Immediate
During 
running
P
H11 19
Maximum 
running 
speed of 2nd 
displacement 
1–6000 rpm 200 Immediate
During 
running
P
H11 20
Acceleration/
Deceleration 
time of 2nd 
displacement
0–65535 ms (s) 10 Immediate
During 
running
P
H11 21
Waiting time 
after 2nd 
displacement
0–10000 ms (s) 10 Immediate
During 
running
P
H11 22 3rd displacement
-1073741824 
to 1073741824
Reference 
unit
10000 Immediate
During 
running
P
H11 24
Maximum 
running speed of 
3rd displacement 
1–6000 rpm 200 Immediate
During 
running
P
H11 25
Acceleration/
Deceleration 
time of 3rd 
displacement<
0–65535 ms (s) 10 Immediate
During 
running
P
H11 26
Waiting time 
after 3rd 
displacement
0–10000 ms (s) 10 Immediate
During 
running
P
H11 27 4th displacement
-1073741824 
to 1073741824
Reference 
unit
10000 Immediate
During 
running
P
H11 29
Maximum 
running speed of 
4th displacement 
1–6000 rpm 200 Immediate
During 
running
P
H11 30
Acceleration/
Deceleration 
time of 4th 
displacement<
0–65535 ms (s) 10 Immediate
During 
running
P