RAID Software Users Guide 5
RAID mode 0 is not fault tolerant. With RAID 0, if a drive fails, then the data is no longer
complete and no longer available. Backplane fault tolerance can be achieved by a spanned
array where the arrays are on different backplanes.
True fault tolerance includes the automatic ability to restore the RAID array to redundancy so
that another drive failure will not destroy its usability.
Hot Spare
True fault tolerance requires the availability of a spare disk that the controller can add to the
array and use to rebuild the array with the data from the failed drive. This spare disk is called a
hot spare. It must be a part of the array before a disk failure occurs. A hot-spare drive is a
physical drive that is maintained by the RAID controller but not actually used for data storage
in the array unless another drive fails. Upon failure of one of the array’s physical drives, the
hot-spare drive is used to hold the recreated data and restore data redundancy.
Hot-spare drives can be global (available to any array on a controller) or dedicated (only
usable by one array). There can be more than one hot spare per array and the drive of the
closest capacity is used. If both dedicated and global hot-spare drives are available, then the
dedicated drive is used first. If the hot swap rebuild fails, then that hot spare is also marked
failed. Since RAID 0 is not redundant, there is no hot spare value.
If a hot-spare drive is not an option, then it is possible to perform a hot or cold swap of the
failed drive to provide the new drive for rebuild after the drive failure. A swap is the manual
substitution of a replacement drive in a disk subsystem. If a swap is performed while the
system is running, it is a hot swap. A hot swap can only be performed if the backplane and
enclosure support it. If the system does not support hot-swap drives, then the system must be
powered down before the drive swap occurs. This is a cold swap.
In all cases (hot spare, hot swap, or cold swap), the replacement drive must be at least as large
as the drive it replaces. In all three cases, the failed drive is removed from the array. If using a
hot spare, then the failed drive can remain in the system. When a hot spare is available and an
automatic rebuild starts, the failed drive may be automatically removed from the array before
the utilities detect the failure. Only the event logs show what happened.
If the system is shut down during the rebuild, all rebuilds should automatically restart
on reboot.
Note: If running a sliced configuration (RAID 0, RAID 5, and RAID 6 on the same set of physical drives),
then the rebuild of the spare will not occur until the RAID 0 array is deleted.
On Intel
®
RAID Controller RS2WC080 and RS2WC040, if Virtual Drive is in degrade mode
due to failed physical drive, auto rebuild is not supported for hot-plugged drive until a manual
selection is made by users. As part of JBOD implementation for Intel
®
RAID Controller
RS2WC080 and RS2WC040, all new drives that are hot-plugged will automatically become
JBOD. Users need to manually move the JBOD drive to Unconfigured Good and auto rebuild
starts after that. For more details, refer to Hardware User's Guide (HWUG) for
above controllers.
Data Redundancy
Data redundancy is provided by mirroring or by disk striping with parity stripes.
Disk mirroring is found only in RAID 1 and 10. With mirroring, the same data
simultaneously writes to two disks. If one disk fails, the contents of the other disk can be

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals