RAID Software Users Guide 47
Forcing a Drive Online or Offline
You can force a drive offline so that a hot-spare replaces it. Power failures may cause a drive to
go offline and you must force it back online.l To force a drive online or offline, follow these
steps:
1. On the Main Menu, select Objects and then Physical Drive.
2. Highlight a physical drive that is a member of an array and press the <Enter> key.
3. From the menu, choose one of the following:
Force Offline to take the drive off line. If the drive was online, its status changes to
FAIL.
Force Online to bring the drive on line. If the drive was offline, its status changes to
ONLINE.
Configuring a Bootable Virtual Drive
Follow these steps to configure a bootable virtual drive:
1. From the Main Menu, select Configure | Select Boot Drive.
2. Select a virtual drive from the list to make it the designated boot drive.
Note: You should also check the system BIOS Setup utility for the boot order setting. To access the BIOS
Setup utility, press the <F2> key when prompted during POST.
Deleting (Clearing) a Storage Configuration
Caution: Before you clear a storage configuration, back up all the data you want to keep.
To clear a storage configuration, follow these steps:
1. On the Main Menu, select Configure | Clear Configuration.
2. When the message appears, select Ye s to confirm. All virtual drives are deleted from the
configuration.

Table of Contents