120 Intel
®
RAID Software Users Guide
Background Initialization (BGI) Rate Enter a number from 0 to 100 to control the
rate at which virtual disks are initialized in the background. Background
initialization makes the virtual disk immediately available for use, even while the
initialization is occurring. The higher the number, the faster the initialization occurs.
However, if a higher number is selected, the system I/O rate may be slower.
Check Consistency Rate. Enter a number from 0 to 100 to control the rate at which
a consistency check is done. A consistency check scans the consistency data on a
fault tolerant virtual disk to determine if the data is corrupted. The higher the
number, the faster the consistency check is done. However, if a higher number is
selected, the system I/O rate may be slower.
Reconstruction Rate. Enter a number from 0 to 100 to control the rate at which
reconstruction of a virtual disk occurs. The higher the number, the faster the
reconstruction will occur. However, if a higher number is selected, the system I/O
rate may be slower.
4. Click OK to accept the new task rates.
5. When the warning message is displayed, click OK to confirm that you want to change
the task rates.
Note: The Controller Go To tab also has options for disabling or silencing the alarm on the controller.
Ordinarily, you should leave the alarm enabled so it can warn you of abnormal conditions on the
controller. If the alarm is malfunctioning, you may need to silence it.
Adding a Drive to a Virtual Disk
You can use Intel
®
RAID Web Console 2 to increase the capacity of an existing virtual disk by
adding physical disk drives to it. In order to do this, you must be logged on to the system in All
Access mode.
Warning: Before you change a virtual disk’s capacity, back up the data on the virtual disk.
To increase the capacity of a virtual disk, follow these steps:
1. User Logical View and select a Drive Group icon in the left panel and then select Go To
-> Drive Group -> Modify Drive Group.

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals