Intel
®
RAID Software Users Guide 109
Figure 53. Option to Close the Configuration Wizard
If you select Ye s, the configuration procedure closes. If you select No, the dialog box
closes and you remain on the same page.
Creating a Virtual Drive Using Advanced Configuration
The advanced configuration procedure provides an easy way to create a new storage
configuration. Advanced configuration gives you greater flexibility than simple configuration
because you can select the drives and the virtual drive parameters when you create a virtual
drive. In addition, you can use the advanced configuration procedure to create spanned drive
groups.
Follow these steps to create a new storage configuration in the advanced configuration mode.
In this example, we will create a spanned drive group.
1. Perform either of the following steps:
Right click on the controller node in the device tree in the left frame of the Intel
®
RAID Web Console 2 window and select Create Virtual Drive
Select the controller node and select Go To -> Controller -> Create Virtual Drive in
the menu bar, as shown in
Figure 54

Table of Contents

Other manuals for Intel SC5650BCDP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SC5650BCDP and is the answer not in the manual?

Intel SC5650BCDP Specifications

General IconGeneral
BrandIntel
ModelSC5650BCDP
CategoryServer
LanguageEnglish

Related product manuals