Status Commands
Copyright © Itech Electronic Co., Ltd. 5
Arguments
<0-65535>
Example
STAT:OPER:PTR 32
Query syntax
STATus:OPERation:PTRansition?
Returns
NR1
STATus:QUEStionable[:EVENt]?
This command can be used to read the value in query event register.The power
supply will return a decimal number corresponding to the binary weighted sum
of each unit digit of register. These digits will be latched. After executing this
command, the query event register will be cleared.
Syntax
STATus:QUEStionable[:EVENt]?
Arguments
None
Example
STAT:QUES?
Returns
NR1
STATus:QUEStionable:CONDition?
This command is used to read the value of query condition register and
gets the status of power supply.
Syntax
STATus:QUEStionable:CONDition?
Arguments
None
Example
STAT:QUES:COND?