Source Commands
Copyright © Itech Electronic Co., Ltd. 46
Example
CURR:PROT:DEL 10.00
Query syntax
[SOURce:]CURRent[:OVER]:PROTection:DELay? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]CURRent[:OVER]:PROTection:STATe
<bool>
This command enables or disables the over-current function.
Syntax
[SOURce:]CURRent[:OVER]:PROTection:STATe <bool>
Arguments
0|OFF|1|ON
Default value
0
Example
CURR:PROT:STAT ON
Query syntax
[SOURce:]CURRent[:OVER]:PROTection:STATe?
Returns
0|1
[SOURce:]CURRent:UNDer:PROTection[:LEVel]
<NRf+>
This command sets the under-current limit of the power supply.
Syntax
[SOURce:]CURRent:UNDer:PROTection[:LEVel] <NRf+>
Arguments
<NRf+> MIN TO MAX