EasyManuals Logo
Home>ITech>Power Supply>IT-M3400 Series

ITech IT-M3400 Series Programming Guide

ITech IT-M3400 Series
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Source Commands
Copyright © Itech Electronic Co., Ltd. 52
Default value
MIN
Example
VOLT:TRIG 60.00
Query syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]VOLTage:SLEW[:BOTH] <NRf+>,<NRf+>
This command sets the voltage rising and falling slew rate of the power supply.
Syntax
[SOURce:]VOLTage:SLEW[:BOTH] <NRf+>,<NRf+>
Arguments
<MINimum-MAXimum>|MINimum|MAXimum
Default value
MAXimum
Example
VOLT:SLEW MAX,MAX
Query syntax
[SOURce:]VOLTage:SLEW[:BOTH]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]VOLTage:SLEW:NEGative <NRf+>
This command sets the voltage falling slew rate of the power supply.
Syntax
[SOURce:]VOLTage:SLEW:NEGative <NRf+>
Arguments
<NRf+>

Table of Contents

Other manuals for ITech IT-M3400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3400 Series and is the answer not in the manual?

ITech IT-M3400 Series Specifications

General IconGeneral
BrandITech
ModelIT-M3400 Series
CategoryPower Supply
LanguageEnglish

Related product manuals