Source Commands
Copyright © Itech Electronic Co., Ltd. 52
Default value
MIN
Example
VOLT:TRIG 60.00
Query syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]VOLTage:SLEW[:BOTH] <NRf+>,<NRf+>
This command sets the voltage rising and falling slew rate of the power supply.
Syntax
[SOURce:]VOLTage:SLEW[:BOTH] <NRf+>,<NRf+>
Arguments
<MINimum-MAXimum>|MINimum|MAXimum
Default value
MAXimum
Example
VOLT:SLEW MAX,MAX
Query syntax
[SOURce:]VOLTage:SLEW[:BOTH]? [MINimum|MAXimum]
Returns
NR3
[SOURce:]VOLTage:SLEW:NEGative <NRf+>
This command sets the voltage falling slew rate of the power supply.
Syntax
[SOURce:]VOLTage:SLEW:NEGative <NRf+>
Arguments
<NRf+>