Source Commands
Copyright © Itech Electronic Co., Ltd. 60
Syntax
[SOURce:]FUNCtion <CV|CC|VOLTage|CURRent>
Arguments
<CV|CC|VOLTage|CURRent>
Default value
VOLTage
Example
FUNC VOLT
Query syntax
[SOURce:]FUNCtion?
Returns
<CV|CC|VOLTage|CURRent>
[SOURce:]UUT:TEMPerature:PROTection[:STATe]
This command sets the UUT over temperature protection status of the power
supply.
Syntax
[SOURce:]UUT:TEMPerature:PROTection[:STATe]
Arguments
<0|1|OFF|ON>
Default value
0
Example
UUT:TEMP:PROT 1
Query syntax
[SOURce:]UUT:TEMPerature:PROTection[:STATe]?
Returns
0|1
[SOURce:]UUT:TEMPerature:PROTection[:LEVel]
<NRf+>
This command sets the UUT over-temperature limit of the power supply.

Table of Contents