Source Commands
Copyright © Itech Electronic Co., Ltd. 55
Arguments
0|OFF|1|ON
Default value
0
Example
VOLT:APROT:STAT ON
Query syntax
[SOURce:]VOLTage[:OVER]:PROTection:STATe?
Returns
0|1
[SOURce:]VOLTage:UNDer:PROTection[:LEVel]
<NRf+>
This command sets the under-voltage limit of the power supply.
Syntax
[SOURce:]VOLTage:UNDer:PROTection[:LEVel] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MIN
Example
VOLT:UND:PROT 10.00
Query syntax
[SOURce:]VOLTage:UNDer:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]VOLTage:UNDer:PROTection:DELay
<NRf+>
This command sets the under-voltage delay time of the power supply.