Output Commands
Copyright © Itech Electronic Co., Ltd. 32
OUTPut:DELay[:RISE] <NRf+>
This command sets the delay time before turning the output on.
Syntax
OUTPut:DELay[:RISE] <NRf+>
Arguments
<0.000-10.000>
Default value
0.000S
Example
OUTP:DEL 1.0
Query syntax
OUTPut:DELay[:RISE]? [MINimum|MAXimum]
Returns
NR3
OUTPut:DELay:FALL <NRf+>
This command sets the delay time after turning the output off.
Syntax
OUTPut:DELay:FALL <NRf+>
Arguments
<0.000-10.000>
Default value
0.000S
Example
OUTP:DEL:FALL 1.0
Query syntax
OUTPut:DELay:FALL? [MINimum|MAXimum]
Returns
NR3