EasyManuals Logo
Home>ITech>Power Supply>IT-M3400 Series

ITech IT-M3400 Series Programming Guide

ITech IT-M3400 Series
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Source Commands
Copyright © Itech Electronic Co., Ltd. 47
Default value
MIN
Example
CURR:UND:PROT 0.500
Query syntax
[SOURce:]CURRent:UNDer:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
<NRf+>
[SOURce:]CURRent:UNDer:PROTection:DELay
<NRf+>
This command sets the under-current delay time of the power supply.
Syntax
[SOURce:]CURRent:UNDer:PROTection:DELay <NRf+>
Arguments
<0-10>
Default value
10.00S
Example
CURR:UND:PROT:DEL 10.000
Query syntax
[SOURce:]CURRent:UNDer:PROTection:DELay? [MINimum|MAXimum]
Returns
<NRf+>
[SOURce:]CURRent:UNDer:PROTection:STATe <bool>
This command enables or disables the under-current function.
Syntax
[SOURce:]CURRent:UNDer:PROTection:STATe <bool>
Arguments
<0|OFF|1|ON>