Battery Commands
Copyright © Itech Electronic Co., Ltd. 76
Chapter13 Battery Commands
BATTery:MODE <CHARge|DISCharge>
This command is used to set the mode of battery test: charging or discharging.
Syntax
BATTery:MODE <CHARge|DISCharge>
Arguments
CHARge|DISCharge
Default value
CHARge
Example
BATTery:MODE CHAR
Query syntax
BATTery:MODE?
Returns
CHARge|DISCharge
BATTery:CHARge:VOLTage <NRf+>
This command is used to set the battery charging voltage value.
Syntax
BATTery:CHARge:VOLTage <NRf+>
Arguments
<MINimum-MAXimum|MINimum|MAXimum>
Example
BATT:CHAR:VOLT 5.0
Query syntax
BATTery:CHARge:VOLTage? [MINimum|MAXimum]
Returns
NR3