Source Commands
Copyright © Itech Electronic Co., Ltd. 57
Syntax
[SOURce:]VOLTage:UNDer:PROTection:WARM <NRf+>
Arguments
<NRf+>
Default value
10.00S
Example
VOLT:UND:PROT:WARM 10.00
Query syntax
[SOURce:]VOLTage:UNDer:PROTection:WARM? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]POWer:LIMit[:IMMediate][:AMPLitude]
<NRf+>
This command sets the maximum setting voltage limit of the power supply.
Syntax
[SOURce:]POWer:LIMit[:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX
Example
POW:LIM 900.0
Query syntax
[SOURce:]POWer:LIMit[:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]POWer:PROTection[:LEVel] <NRf+>
This command sets the over-power limit of the power supply.