Output Commands
Copyright © Itech Electronic Co., Ltd. 34
OUTPut:SDS[:STATe]?
This command is used to query the SDS status.
Syntax
OUTPut:SDS[:STATe]?
Arguments
None
Default value
None
Example
OUTP:SDS?
Returns
0|1
0: indicates not connecte SDS, 1: indicates the SDS is connected.
OUTPut:SDS:ENABle <0|OFF|1|ON>
This command is used to enable or disable the SDS module.1: indicates enable,
0: indicates disable.
Syntax
OUTPut:SDS:ENABle <0|OFF|1|ON>
Arguments
<0|OFF|1|ON>
Default value
1
Example
OUTP:SDS:ENAB 1
Returns
0|1
OUTPut:SDS:DC:RELay <0|OFF|1|ON>
This command is used to open or close the main circuit DC relay, 0 indicates
open, 1 indicates close.