Trace Commands
Copyright © Itech Electronic Co., Ltd. 66
TRACe:DATA?
This command reads all values saved in the cache.
Note
Before sending the query command TRACe:DATA?, the command TRIGger[:IMMediate]
must be sent to the instrument to trigger the instrument into data storage status. And the
argument of the command TRACe:FEED:CONTrol <NEXT|ALWays|NEVer> must be set
to NEXT or ALWays, otherwise the system will prompt an error.
Syntax
TRACe:DATA?
Arguments
None
Example
TRACe:DATA?
Returns
<NRf>,<NRf>,<NRf>.....
TRACe:FILTer[:STATe]
This command enables or disables the filter.
Syntax
TRACe:FILTer[:STATe]
Arguments
<0|1|OFF|ON>
Default value
OFF
Example
TRAC:FILT 0
Returns
0|1