Status Commands
Copyright © Itech Electronic Co., Ltd. 6
Returns
NR1
STATus:QUEStionable:ENABle <n>
This command edits the enable register value of query event. In query, the
power supply will return a decimal number representing the binary weighted
sum of the enable register.
Syntax
STATus:QUEStionable:ENABle <n>
Arguments
<0-65535>
Example
STAT:QUES:ENAB 24
Query syntax
STATus:QUEStionable:ENABle?
Returns
NR1
STATus:QUEStionable:NTRansition <n>
This command is used to edit the negative transition trigger register of
query event.
Syntax
STATus:QUEStionable:NTRansition <n>
Arguments
<0-65535>
Example
STAT:QUES:NTR 64
Query syntax
STATus:QUEStionable:NTRansition?
Returns
NR1