Source Commands
Copyright © Itech Electronic Co., Ltd. 43
Chapter10 Source Commands
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]
<NRf+>
This command sets the current value of the power supply. The query form of
this command gets the set current value of the power supply.
Syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+> MIN TO MAX
Default value
MAX
Example
CURR 3.500
Query syntax
[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [MINimum|MAXimum]
Returns
NRf+
[SOURce:]CURRent[:LEVel]:LIMit:POSitive <NRf+>
This command sets the positive current limit value of the power supply.
Syntax
[SOURce:]CURRent [:LEVel]:LIMit:POSitive <NRf+>
Arguments
<MINimum-MAXimum>|MINimum|MAXimum
Default value
0.0
Example
CURR:LIM:POS MAX