Section C - Electrics
C - 1 C - 1
9803-9450-1
Technical Data
General Electrical Data
Light Bulbs
System Type 12 Volts, negative earth
Battery up to machine number 680579
Cold Crank Amps for 1 minute to 1.4 VPC at -18 °C (0 °F) 420 to 585 according to battery type
Reserve capacity (minutes) for 25 Amp load 170 to 230 according to battery type
Battery from machine number 680580
Cold Crank Amps for 1 minute to 1.4 VPC at -18 °C (0 °F) 535
Reserve capacity (minutes) for 25 Amp load 135
Alternator
Robot 190 A127-65 or A1151-65, 65 Amp max. output
Robot 1110 A127-65, 65 Amp max. output or A1151-75, 75 Amp max.
output
Starter M127
Working Lights 55W (Halogen)
Headlights 55W (Halogen)
Indicator Lights 21W
Brake Lights 21W
Interior Light 10W
Warning Lights 1.2W
Beacon (if fitted) 55W
Side Lights 5W