Section E - Hydraulics
Pressure Testing
Transmission Charge Pressure
E - 62 E - 62
9803-9450-2
Transmission Charge Pressure
1 Make sure that the hydraulic fluid is at correct working
temperature (50 °C, 122 °F).
2 Stop engine. Connect a 0 - 40 bar (0 - 600 lb/in
2
, 0 -
42 kg/cm
2
) pressure gauge into test point X1 at the
hydraulic filter.
3 Start engine and check pressure is as specified in
Technical Data.
4 If the pressure is not as specified, stop the engine.
Unscrew locknut 16 and turn adjuster 17 quarter of a
turn at a time (clockwise to increase pressure) then
re-tighten locknut. Start engine and re-check
pressure. Continue procedure until pressure is
correct then remove pressure gauge.
Fig 49.
Fig 50.
X1
16
17