Section 3 - Maintenance
Routine Maintenance
Electrical System
3 - 25 3 - 25
9803/9450-1
Electrical System
Battery
The battery is mounted in the engine compartment.
Fig 9. Battery Installation
Battery Disconnection/Connection
T3-019_2
!MWARNING
Keep metal watch straps and any metal fasteners on
your clothes, clear of the positive (+) battery terminal.
Such items can short between the terminal and nearby
metal work. If it happens you can get burned.
5-2-2-4
Disconnection
1 Open the battery compartment. See Battery Cover.
2 Remove the leads. Disconnect the earth (-) terminal
first.
Connection
1 Check the battery.
a If the terminal is dirty, clean the post.
Fig 10.
b If the terminal post is corroded and generates
white powder wash the terminal with hot water. If
considerable corrosion is detected, clean with a
wire brush or abrasive paper.
c After cleaning, apply a thin coat of petroleum jelly
to the terminal.
2 Re-connect the leads. Connect the earth (-) terminal
last.
3 Close and lock the battery compartment.
Checking the Electrolyte Level
T3-020
Maintenance free batteries used in normal temperate
climate applications should not need topping up. However,
in certain conditions (such as prolonged operation at
tropical temperatures or if the alternator overcharges) the
electrolyte level should be checked as described below.
1 Open the battery compartment cover. See Battery
Cover.
2 Disconnect and remove battery. See Battery
Disconnection/Connection.
!MWARNING
Do not top the battery up with acid. The electrolyte
could boil out and burn you.
2-3-4-6