Section C - Electrics
Technical Data
Sensing Switches
C - 2 C - 2
9803-9450-1
Sensing Switches
Fig 1.
Fig 2.
Fig 3.
A Transmission Charge Pressure Switch. Normally
closed, opens at 2-3.4 bar (30-50 lbf/in
2
) falling.
B Transmission Oil Temperature Switch. Normally
open, closes at 107-113 °C (225-235 °F) rising.
D Reverse Alarm Pressure Switches. Normally open,
closes at 7 bar (100 lbf/in
2
) rising.
F Brake Light Pressure Switches. Normally open,
closes at 4 bar (58 lbf/in
2
) rising.
H Float Pressure Switch. Normally closed, opens at
40 bar (580 lbf/in
2
) rising.
A
B
F
D
D
F
C045550
H