Section E - Hydraulics
Pressure Testing
Power Management System (P.M.S.)
E - 66 E - 66
9803-9450-2
To fit Sensitivity Control to Non High
Flow Machines
Fig 56.
Sensitivity control F is a standard fitting on High Flow
machines. This control can be fitted to non High Flow
machines to provide improved control of standard flow
attachments.
1 Remove front switch panel. Make sure that the panel
is drilled to accept the control.
Fig 57.
2 Locate the socket fed by wires 660 and 660A.
Remove linking plug H from the socket. Fit blank 719/
10101 in place of linking plug H.
Fig 58.
3 Remove blanking plug from connector D K
Fig
55. ( T E-64) (fed by wire numbers 144B, 509 and
600AH). Connect potentiometer E into the harness as
shown.
4 Fit the potentiometer to the switch panel and refit the
panel. Fit knob F.
5 Do the System Check K
System Check ( T E-50).
Parts Required
716/30334 Potentiometer (E)
331/21736 Knob (F)
719/10101 Blank
/
.