EasyManua.ls Logo

jcb Robot 160 - Page 261

jcb Robot 160
355 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section E - Hydraulics
Pressure Testing
Power Management System (P.M.S.)
E - 64 E - 64
9803-9450-2
Fig 53.
5 On machines not fitted with sensitivity control F:
a Remove front switch panel.
Fig 54.
b Locate the socket fed by wires 660 and 660A.
Remove linking plug H from the socket.
Fig 55.
c Remove blanking plug from connector D K
Fig
55. ( T E-64) (fed by wire numbers 144B, 509 and
600AH). Connect potentiometer E into the
harness as shown. Potentiometer is part number
716/30334. If required, fit knob 331/21736.
d Turn potentiometer E fully clockwise.
6 On machines fitted with sensitivity control F (standard
fitting on High Flow machines), turn control F fully
clockwise.
7 On all machines:
Set up a tachometer to read engine speed from either
the crankshaft pulley or the fan pulley.
Note: The tachometer reading on the fan pulley will be
higher than crankshaft speed K
Table 13. ( T E-65).
8 Press button C, switch on ignition until red light G on
instrument panel begins to flash (1 flash per second),
K
Fig 53. ( T E-64). Then release button C.
9 Start engine. Gradually increase engine speed until
the tachometer shows the speed shown at stage 1
K
Table 13. ( T E-65). Turn potentiometer or control
F until pressure gauge reads 10 bar (145 lb/in
2
).
/
.
66
0
660A
H
E
D

Table of Contents

Related product manuals