SECTION 5 - JLG CONTROL SYSTEM
3121166 – JLG Lift – 5-25
5.8 MACHINE MODEL ADJUSTMENT - SEVCON - 1600346 POWER MODULE
NOTE: These settings may change in order to achieve optimal performance on a machine by machine basis.
Table 5-3. Machine Model Adjustment
(Machines with Sevcon - 1600346 Power Module Only)
Adjustment Adjustment Range 1930ES 2030ES 2630ES 2646ES 3246ES
DRIVE
ACCEL 0.1 - 5.0 (Sec) 0.7 0.7 0.7 0.7 0.7
DECEL 0.1 - 1.0 (Sec) 0.1 0.1 0.1 0.1 0.1
MINIMUM 0 - 25% 0 0 0 0 0
MAXIMUM 0 -100% 100 100 100 100 100
ELEV. MAX. 0 - 25% 18 16 16 20 20
LIFT
ACCEL 0.1 - 5.0 (Sec) 0.5 0.5 0.5 0.5 0.5
DECEL 0.1 - 1.0 (Sec) 0.1 0.1 0.1 0.1 0.1
UP MIN 0 - 50% 20 20 20 20 20
UP MAX 0 - 100% 100 100 100 100 100
DN MIN 1 - 60% 18 45 42 52 52
DN MAX 1 - 100% 60 85 63 80 80
STEER
STATIC 0 - 100% 50 50 50 50 50
DRIVE 0 - 100% 30 30 30 30 30
ACCELERATOR
FWD MIN 2.20 - 2.40 V 2.25 2.25 2.25 2.25 2.25
FWD MAX 1.00 - 1.50 V 1.20 1.20 1.20 1.20 1.20
REV MIN 2.60 - 2.80 V 2.75 2.75 2.75 2.75 2.75
REV MAX 3.50 - 4.00 V 3.80 3.80 3.80 3.80 3.80
GROUND
HORN 87 - 107 dB 107 107 107 107 107
ALARM 87 - 107 dB 87 87 87 87 87
LOAD
ACCY 0 - 200 Kg 0 0 0 0 0
OVR DBNCE 0.0 - 5.0 Sec 3.0 3.0 3.0 3.0 3.0
OVR HOLD 0.0 - 5.0 Sec 5.0 5.0 5.0 5.0 5.0
4150472-H