SECTION 6 - DIAGNOSTIC TROUBLE CODES
6-14 – JLG Lift – 3121166
662 CANBUS FAILURE - PLAT-
FORM MODULE
In platform mode, the control system
failed to receive messages from the plat-
form board.
Turn on machine in ground mode. If DTC 661 is not present check
for 24V between platform box connector terminals D and A. If not
24V, test continuity from platform box connector socket A to
ground board connector socket J1-6 and test continuity from plat-
form box connector socket D to ground board connector socket
J1-7.
If DTC 661 was present in the previous check, disconnect arm-
stack passthru connector located near the ladder on the left. Turn
on in ground mode. If DTC 661 is not present then there is a prob-
lem in armstack harness. Armstack passthru socket 5 to platform
box terminal E should have continuity. Armstack passthru socket
6 to platform box connector terminal F should have continuity.
Armstack passthru socket 7 to platform box connector terminal G
should have continuity. Armstack passthru socket 5 to armstack
passthru socket 6 resistance should be 120 Ohms +/- 5%. Arm-
stack passthru socket 5 to armstack passthru socket 7 should
measure open circuit. Armstack passthru socket 6 to armstack
passthru socket 7 should measure open circuit.
Disconnect armstack passthru and ground board J1. Armstack
passthru pin 5 to ground board socket J1-11 should have conti-
nuity. Armstack passthru pin 6 to ground board socket J1-12
should have continuity. Armstack passthru pin 7 to ground board
socket J1-13 should have continuity. Armstack passthru pin 5 to
armstack passthru pin 6 should measure open circuit. Armstack
passthru pin 5 to armstack passthru pin 7 should measure open
circuit. Armstack passthru pin 6 to armstack passthru pin 7
should measure open circuit.
Disconnect ground board J1 and power module connector.
Ground board socket J1-31 to power module connector socket
10 should have continuity. Ground board socket J1-32 to power
module connector socket 11 should have continuity. Ground
board socket J1-31 to J1-32 should measure open circuit.
Ground board socket J1-31 to J1-33 should measure open cir-
cuit. Ground board socket J1-32 to J1-33 should measure open
circuit.
Ensure all connections opened above are reconnected. Discon-
nect power module connector. Turn on in platform mode. If DTC
662 is no longer present replace power module.
If DTC 661 and 662 have been present through above steps
replace ground board.
Continued Next Page
662
(Cont.)
CANBUS FAILURE - PLAT-
FORM MODULE
(Continued)
In platform mode, the control system
failed to receive messages from the plat-
form board.
Disconnect platform box connector. Open platform box. Discon-
nect platform board connector. Platform box socket E to platform
board J1-3 should have continuity. Platform box socket F to plat-
form board J1-4 should have continuity. Platform box pin E to pin
F should measure open circuit. Platform box pin E to pin G should
measure open circuit. Platform box pin F to pin G should measure
open circuit. If these checks are OK replace platform board.