3-58
Step Operation IME/DTE Response Remarks
1
Move the cursor to
“Transmit” and press
Enter key.
The “Transmit” window
is displayed.
2
Move the cursor to the
“Closed network” and
press
Enter key.
The “Closed network”
window is displayed.
“Closed network” is
the optional facility for
each LES.
3
Move the cursor to the
“Closed network id” and
press
Enter key.
The cursor is moved to
right entry field from
“Closed network id”.
4
When the closed network
ID is selected, press
F2
(“DNID list”) key.
The “Closed network list
window” is displayed.
When the closed network
ID is not downloaded, the
blank list is displayed.
When the closed
network ID is not
downloaded, the blank
list is displayed.
5
Select the closed network
ID by
and key and
press Enter key.
The cursor is moved to
“File name”.
6
When the file is selected,
press
Enter key.
The cursor is moved to
right column from “File
name”.
7
Press
F2 (“File selection”)
key.
The “File list” window is
displayed.
8
Select the file by
, key
and press Enter key.
The contents of the file are
displayed.
When the file name is
knowledge, type the file
name directly.
Note 1, 2
9
After confirmation of the
contents and press
F10
(“Previous”) key.
The “File list” window is
displayed.
10
Press
F10 (“Previous”)
key to return the “Closed
network” window.
The cursor is moved to
“land Earth station
(les)”.
11
When the LES is selected,
press
Enter key.
The cursor is moved to
right column from “land
Earth station (les)”.
When the LES ID is
knowledge, type the
LES ID directly.
12
Press
F2 (“LES list”) key.
The “LES list” window is
displayed.
When the JUE-87 is not
synchronized to
satellite, the blank list is
displayed.
13
Select the LES ID by
,
key, and press Enter key.
The cursor is moved to
“posItion”.
Note 3