EasyManuals Logo

Juniper SRX Series User Manual

Juniper SRX Series
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
Using the J-Web Interface
To perform basic configuration for the 1-Port T1/E1 Mini-Physical Interface Module and
to configure network interfaces for the services gateway using the J-Web interface:
1. In the J-Web interface, select Configure>Interfaces>Ports.
The Interfaces page displays and lists the network interfaces present on the services
gateway, along with configuration information (if configured).
2. To configure properties for a network interface (Mini-PIM), select the interface name
(t1-1/0/0 or e1–1/0/0), and click Edit.
3. To use the port on the Mini-PIM, you must assign it to a security zone other than the
Null zone. Optionally, you can also assign the port an IP address (for example,
192.168.3.1/24). Enter or select the following settings:
a. Select Configure>Security>Zones.
b. Add or select a security zone other than Null; for example, Trust.
c. For host inbound traffic, set the following:
•
System Services=Allow All
•
Protocols=Allow All
d. Click OK to save changes, and click Commit to apply the configuration and other
pending changes (if any).
4. To use the port on the Mini-PIM, you must also set security policies. Select the following
settings:
a. Select Configure>Security>Policy>Apply Policy.
b. Set Policy Action: Default Policy Action=Permit-All.
c. Click OK to save changes, and click Commit to apply the configuration and other
pending changes (if any).
For advanced configuration information, see the Junos OS Network Interfaces
Configuration Guide.
Using the CLI
To perform basic configuration for the 1-Port T1/E1 Mini-PIM (for the T1 interface) and to
configure network interfaces for the services gateway with the CLI:
•
Verify that the T1/E1 interface is installed on the device:
show chassis hardware
•
Verify the status of the interface:
show interfaces terse
•
Assign the port an IP address:
Copyright © 2015, Juniper Networks, Inc.216
SRX Series Services Gateways for the Branch Physical Interface Modules Reference

Table of Contents

Other manuals for Juniper SRX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX Series and is the answer not in the manual?

Juniper SRX Series Specifications

General IconGeneral
CategoryGateway
Operating SystemJunos OS
Product FamilySRX Series
PurposeSecurity
VPN ThroughputVaries greatly depending on the specific model, ranging from Gbps to Tbps
Power SupplyVaries depending on the specific model (e.g., AC, DC, Redundant)