EasyManua.ls Logo

Keba KeDrive D3-DU 3 A Series - Only for D3-DU 3 X5;X) Safe Digital Outputs (SDO) 0.5 a; Only for D3-DU 3 X5;X) Safe Digital Outputs (SDO) 2 a

Keba KeDrive D3-DU 3 A Series
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D3-DU 3xx/A, /B Technical data
Project engineering manual V1.09
115
© KEBA 2021
Safety Category:
Single input: Up to category 3, PL d, SIL2
Redundant input: Up to category 4, PL e, SIL3
Effect by incorrectly connected inputs:
Potential defect, if current > 32 V is con-
nected
Recommended length for cables and con-
nection lines:
< 30 m
Delay time in the transition (0 to 1 / 1 to 0):
12.7 (Only for D3-DU 3x5/x) Safe digital outputs (SDO) 0.5 A
Quantity: 8 (SDO0 - SDO7)
Type:
Protected output (according to EN 61131-2),
non storing
Nominal voltage: 24 V DC PELV
Norminal current: 0,5 A
Inductive load (Energy): 100 mJ at 0.2 Hz
Capacitive load: Max. 100 nF
Status display: Orange LED
Cross circuit-proof: Yes
Overload protection: Yes
Isolation: No
Safety Category:
Single output: Up to category 3, PL d, SIL 2
Redundant output: Up to category 4
*)
, PL e, SIL3
Output testing:
Always active (Test pulse: max. 600 μs, mini-
mum range between two test pulse: 4 ms)
Voltage at switched of output: Max. 2.4 V
Effect by incorrectly connection (external
voltage on output):
Potential defect
*)
Category 4 hence PL e and therefore PL e are only valid, if the following
SDOs pairs are used: SDO0 + SDO1, SDO2 + SDO3, SDO4 + SDO5, ...
12.8 (Only for D3-DU 3x5/x) Safe digital outputs (SDO) 2 A
Quantity: 2 (SDO8 - SDO9)
Type:
Protected output (according to EN 611-31-2),
non storing
Nominal voltage: 24 V DC PELV
Norminal current: 2 A
Inductive load (Energy): 200 mJ at 0.2 Hz
Capacitive load: Max. 200 nF
Status display: Orange LED

Table of Contents

Related product manuals