D3-DU 3xx/A, /B Connections and wiring
Project engineering manual V1.09
59
© KEBA 2021
6.6 Gigabit Ethernet interface
The two Gigabit Ethernet sockets (X41A and X41B) are located on the front
side of the module and are used for communication with non-real-time-capa-
ble networks (LAN and/or visualization systems).
Autocrossing is supported.
6.6.1 Pin assignment
Fig.6-32: Pin assignment RJ45 socket
Pin no. Signal designation Input/output
1 MX0+ Bidirectional
2 MX0- Bidirectional
3 MX1+ Bidirectional
4 MX2+ Bidirectional
5 MX2- Bidirectional
6 MX1- Bidirectional
7 MX3+ Bidirectional
8 MX3- Bidirectional
6.6.2 Cable and plug specification
For details, refer to the system manual.
6.7 Master interface
The DU 3xx/x can be equipped optional with a further master fieldbus inter-
face.
The master interface (X43A and X43B) is located on the front side of the
module and is used for communication in real time operation.
Information
The bottom socket (X43B) is not connected when used as EtherCAT.
Autocrossing is supported.