EasyManuals Logo

Keba KeDrive D3-DU 3 A Series User Manual

Keba KeDrive D3-DU 3 A Series
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
D3-DU 3xx/A, /B Safety notes
Project engineering manual V1.09
19
© KEBA 2021
2.2 General safety instructions
WARNING!
It is absolutely essential that you also observe the safety instructions in
the system manual and the "Functional safety" manual for your automa-
tion system.
The following application areas are expressly excluded for the DU 3xx/x
without completing a special evaluation relating to the application and
implementing the necessary measures in the installation relating to the
operating conditions:
Use in areas where there is a risk of explosion or fire
Use in the mining sector
Use in outdoor areas
Use in wet rooms or rooms with the risk of splashing water
Use in environments with heavily polluted air
Use in environments with harmful solutions, steams or radiations
Use in non-stationary applications
Usage in environments with constant vibrations
Direct use on a DC motor
The module is defined as "open type equipment" (UL 508) or as "open
equipment" (EN 61131-2) and must therefore be installed in a control
cabinet.
The DU 3xx/x contains safety-relevant functions (e.g. STO). For safety-
relevant control tasks and personnel security a control of KEBA in the
variant with correspondent safety related peripheral devices must be
used. Details can be found in the safety manual "Functional safety".
At the developement of the the standard EN ISO 13849-1 or other stan-
dards for description of the functional safety were not considered.
Caution
Improper use of the assembly or the control system leads to irreparable
damage!
Turn off the power supply before inserting or removing the module. Oth-
erwise, the module can be destroyed or undefined signal states can lead
to damage of the control system.
If there are further power supply units in the system, they must also be
turned off, to ensure that no electrical voltages are present at all connec-
tions of the module.
KEBA shall assume no liability or warranty for consequential losses, which
may arise of:
Disregard of directives and standards

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba KeDrive D3-DU 3 A Series and is the answer not in the manual?

Keba KeDrive D3-DU 3 A Series Specifications

General IconGeneral
BrandKeba
ModelKeDrive D3-DU 3 A Series
CategoryControl Unit
LanguageEnglish

Related product manuals