6 Input/Output
6.1 RF Source
IP Address
Sets up the controller’s IP address of Remote Secondary models.
Remote Command
:SOURce:SYNC:REMote:ADDRess <string>
Example
:SOUR:SYNC:REM:ADDR "192.168.1.2"
Notes <string> - IP Address
SCPI Socket Port
Sets up the controller’s SCPI socket port of Remote Secondary models.
Remote Command
:SOURce:SYNC:REMote:IPPort <integer>
Example
:SOUR:SYNC:REM:IPP 5025
Notes <integer> - Port
Add Secondary Module
Lets you connect the remote chassis specified by IP Address and Socket Port.
Remote
Command
:SOURce:SYNC:REMote:ADDRess:ADD
Example
:SOUR:SYNC:REM:ADDR:ADD
Notes Example of how to add a remote chassis:
:SOUR:SYNC:REM:ADDR "192.168.1.2"
:SOUR:SYNC:REM:IPP 5025
:SOUR:SYNC:REM:ADDR:ADD
Once a remote chassis is connected, the "Secondary Module List" on page 707 shows you the available
Secondary modules
Delete Secondary Module
Lets you delete a selected remote chassis IP Address from the "Secondary Module
List" on page 707 .
Remote
Command
:SOURce:SYNC:REMote:ADDRess:DELete
Example
:SOUR:SYNC:REM:ADDR:DEL
Notes Example of how to delete a remote chassis:
:SOUR:SYNC:REM:ADDR "192.168.1.2"