3 Sequencing
124 Keysight M8195A Revision 2 Arbitrary Waveform Generator User’s Guide
RUN
Trigger
Trigger
Stop
(Abort)
Offset
Offset
Last
Value
21 3 4
1 2
Adv Event
Figure 34: Segment advance = repeat
RUN
Trigger
Trigger
Stop
(Abort)
Adv Event Adv Event
Offset
Offset
Last
Last
Last
Last
Last
Value
1
214
32
Value
Value
Value
Value
Adv Event Adv Event Adv Event
Figure 35: Segment advance = single
Trigger
Stop
(Abort)
Offset
Offset
RUN
Figure 36: Segment advance = conditional