Keysight M8195A Revision 2 Arbitrary Waveform Generator User’s Guide 227
The sequence table can contain data and idle delay entries. The following table
shows which parameters are needed to create the different entry types.
Table 33: Sequencer table entries
Parameter Index
Data Entry
Idle Delay Entry
0
Control
Control
1
Sequence Loop Count
Sequence Loop Count
2
Segment Loop Count
Command Code
3
Segment Id
Idle Sample
4
Segment Start Offset
Idle Delay
5
Segment End Offset
0
The following tables show the meaning of the parameters and the applicability per
sequence entry type. Bits marked as “Reserved” or “N/A” must be set to 0.