granularity. Output Sample Rate will be slightly adjusted to keep the input 
waveform time window. 
  Repeat: Output Waveform Length is calculated based on the input 
waveform time window and the user-defined output sampling rate. The 
resulting waveform length will not be, in general, a multiple of the 
granularity. To meet the granularity conditions, the base waveform is 
repeated the minimum number of times so the overall number of samples 
is a multiple of the granularity. Output Sample Rate will be slightly 
adjusted to keep the input waveform time window. The Waveform Length 
field will show the length of the combined waveform. 
  Waveform Length 
It shows the number of samples of the resampled output waveform. It can be 
set when Resampling Mode is Output_RL. Otherwise, this field is an indicator.  
  Source Sample Rate 
The speed at which samples in the input waveform are sampled. It can be set 
by typing a valid value unless the "Use As Source Sample Rate" checkbox is 
checked. In this particular case, the sampling rate information contained in the 
input waveform file will be always used.  
  Baseband Sample Rate 
The speed at which samples in the output waveform will be converted. It can 
be set in all Resampling Modes except for the Output_RL mode.  
  Start Sample 
This field can be used to select the starting sample of the section of the input 
waveform to be imported. It cannot be set to a value higher than the Stop 
Sample.  
  Stop Sample 
This field can be used to select the final sample of the section of the input 
waveform to be imported. It cannot be set to a value lower than the Start 
Sample.  
  Carrier Frequency 
This field is only enabled for the import of Signal Studio encrypted files with 
“Generate I/Q Data” unchecked. It contains the frequency, to which the Signal 
Studio baseband data is up-converted.   
  Carrier Scale 
This field is only enabled for the import of Signal Studio encrypted files with 
“Generate I/Q Data” unchecked. It contains a scaling value, that is applied to 
the samples after up-conversion before they are written to the AWG memory. 
  Optimize Carrier Scale 
This checkbox is only enabled for the import of Signal Studio encrypted files 
with “Generate I/Q Data” unchecked. If checked, an optimal scaling factor is 
computed, so that the up-converted signal uses the whole DAC range. If 
unchecked, the Carrier Scale value is used. 
 
 
Scaling Section 
  Scale 
This checkbox controls the way the output waveform will be scaled. If 
unchecked, the output waveform samples will not be re-scaled. Sample levels 
over +1.0 or under -1.0 will be clipped. 
  DAC Max 
Imported waveforms may occupy a limited range of the DAC’s full scale. This 
parameter sets the maximum level. If set to a lower level than DAC Min, this