2G0947 - 31JAN08 4-3
Preventive Maintenance
Performing the PM
Every PM, perform all of the following procedures in the order listed:
1. Print a “flat-field inspection” film (i.e., gray-out) to compare against the
film after PM is complete.
2. Insert the FILM SAVERS.
3. Press the "unlock" button on the LOCAL PANEL.
NOTE: The FILM TRAY must be removed within 30 seconds after pressing
the "unlock" button. Otherwise, the FILM TRAY will re-lock
automatically.
4. Remove the FILM TRAYS.
5. De-energize the IMAGER (see Installation Instructions, “De-energizing
the IMAGER” on page 2-3).
6. Open:
• TOP COVER.
• FRONT COVER.
• PROCESSOR COVER.
7. Remove:
• LEFT PANEL (see Adjustments And Replacements, “LEFT PANEL”
on page 3-12)
• RIGHT PANEL (see Adjustments And Replacements, “RIGHT
PANEL” on page 3-13)
• FRONT PANEL (see Adjustments And Replacements, “FRONT
PANEL” on page 3-17).