MegaRAID SAS Software User Guide Chapter 4: WebBIOS Configuration Utility
| Creating a Storage Configuration
3. If you need to undo the changes, click Reclaim.
4. Click Accept DG to create a RAID 6 drive group.
An icon for a second drive group displays in the right panel.
5. Click on the icon for the second drive group to select it.
6. Hold <Ctrl> while selecting at least three more ready drives in the Drives panel to
create a second drive group.
7. Click Add To Array to move the drives to a proposed drive group configuration in
the Drive Groups panel on the right, as shown in Figure56.
8. If you need to undo the changes, click Reclaim.
9. Choose whether to use drive encryption.
Figure 56: WebBIOS Drive Group Definition Screen
10. After you finish selecting drives for the drive groups, select each drive group and
click Accept DG for each.
11. Click Next.
The Span Definition screen appears, as shown in Figure57.
This screen displays the drive group holes you can select to add to a span.