MegaRAID SAS Software User Guide Appendix A: Events and Messages
| Event Messages
0x00bd Information SAS/SATA mixing not supported in enclosure; Drive %s
disabled
0x00be Information Enclosure (SES) hotplug on %s was detected, but is not
supported
0x00bf Information Clustering enabled
0x00c0 Information Clustering disabled
0x00c1 Information Drive too small to be used for auto-rebuild on %s
0x00c2 Information BBU enabled; changing WT virtual drives to WB
0x00c3 Warning BBU disabled; changing WB virtual drives to WT
0x00c4 Warning Bad block table on drive %s is 80% full
0x00c5 Fatal Bad block table on drive %s is full; unable to log block %lx
0x00c6 Information Consistency Check Aborted due to ownership loss on %s
0x00c7 Information Background Initialization (BGI) Aborted Due to Ownership
Loss on %s
0x00c8 Critical Battery/charger problems detected; SOH Bad
0x00c9 Warning Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning
threshold exceeded
0x00ca Critical Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical
threshold exceeded
0x00cb Critical Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further
reporting disabled
0x00cc Critical Enclosure %s Power supply %d switched off
0x00cd Information Enclosure %s Power supply %d switched on
0x00ce Critical Enclosure %s Power supply %d cable removed
0x00cf Information Enclosure %s Power supply %d cable inserted
0x00d0 Information Enclosure %s Fan %d returned to normal
0x00d1 Information BBU Retention test was initiated on previous boot
0x00d2 Information BBU Retention test passed
0x00d3 Critical BBU Retention test failed!
0x00d4 Information NVRAM Retention test was initiated on previous boot
0x00d5 Information NVRAM Retention test passed
0x00d6 Critical NVRAM Retention test failed!
0x00d7 Information %s test completed %d passes successfully
0x00d8 Critical %s test FAILED on %d pass. Fail data: errorOffset=%x
goodData=%x badData=%x
0x00d9 Information Self check diagnostics completed
0x00da Information Foreign Configuration detected
0x00db Information Foreign Configuration imported
0x00dc Information Foreign Configuration cleared
0x00dd Warning NVRAM is corrupt; reinitializing
Table 135: Event Messages (Continued)