| Event Messages
0x00de Warning NVRAM mismatch occurred
0x00df Warning SAS wide port %d lost link on PHY %d
0x00e0 Information SAS wide port %d restored link on PHY %d
0x00e1 Warning SAS port %d, PHY %d has exceeded the allowed error rate
0x00e2 Warning Bad block reassigned on %s at %lx to %lx
0x00e3 Information Controller Hot Plug detected
0x00e4 Warning Enclosure %s temperature sensor %d differential detected
0x00e5 Information Drive test cannot start. No qualifying drives found
0x00e6 Information Time duration provided by host is not sufficient for self check
0x00e7 Information Marked Missing for %s on drive group %d row %d
0x00e8 Information Replaced Missing as %s on drive group %d row %d
0x00e9 Information Enclosure %s Temperature %d returned to normal
0x00ea Information Enclosure %s Firmware download in progress
0x00eb Warning Enclosure %s Firmware download failed
0x00ec Warning %s is not a certified drive
0x00ed Information Dirty cache data discarded by user
0x00ee Information Drives missing from configuration at boot
0x00ef Information Virtual drives (VDs) missing drives and will go offline at boot:
%s
0x00f0 Information VDs missing at boot: %s
0x00f1 Information Previous configuration completely missing at boot
0x00f2 Information Battery charge complete
0x00f3 Information Enclosure %s fan %d speed changed
0x00f4 Information Dedicated spare %s imported as global due to missing arrays
0x00f5 Information %s rebuild not possible as SAS/SATA is not supported in an
array
0x00f6 Information SEP %s has been rebooted as a part of enclosure firmware
download. SEP will be unavailable until this process
completes.
0x00f7 Information Inserted PD: %s Info: %s
0x00f8 Information Removed PD: %s Info: %s
0x00f9 Information VD %s is now OPTIMAL
0x00fa Warning VD %s is now PARTIALLY DEGRADED
0x00fb Critical VD %s is now DEGRADED
0x00fc Fatal VD %s is now OFFLINE
0x00fd Warning Battery requires reconditioning; please initiate a LEARN cycle
0x00fe Warning VD %s disabled because RAID-5 is not supported by this RAID
key
0x00ff Warning VD %s disabled because RAID-6 is not supported by this
controller