02010415
02010416
SensorType:Voltage
EventSeverity:Critical
Description:Lower
Non-Recoverable-Going
Low-Asserted
CPU%DDR_VDD
voltageistoolow
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
02010215
02010216
SensorType:Voltage
EventSeverity:Critical
Description:Lower
Critical-GoingLow-
Asserted
CPU%VCORE
voltageistoolow
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
02010015
02010016
SensorType:Voltage
EventSeverity:Warning
Description:Lower
Non-Critical-GoingLow
-Asserted
CPU%VCORE
voltageistoolow
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
02010B15
02010B16
SensorType:Voltage
EventSeverity:Critical
Description:Upper
Non-Recoverable-Going
High-Asserted
CPU%VCORE
voltageistoohigh
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
02010915
02010916
SensorType:Voltage
EventSeverity:Critical
Description:Upper
Critical-GoingHigh-
Asserted
CPU%VCORE
voltageistoohigh
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
02010715
02010716
CPU%_DDR_VDD
(%=CPUnumber)
SensorType:Voltage
EventSeverity:Warning
Description:Upper
Non-Critical-GoingHigh
-Asserted
CPU%VCORE
voltageistoohigh
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
01010B20
SensorType:
TemperatureEvent
Severity:Critical
Description:Upper
Non-Recoverable-Going
High-Asserted
Inlettemperatureis
toohigh
1.Checkambienttemperatureiswithin
environmentspec.2.ChecktheLenovo
supportwebsiteforanapplicabletipor
firmwareupdatethatappliestothiserror.3.
CheckFanstatus.ifFanisbroken,please
replacethenewFan.4.ContactyourLenovo
servicerepresentativeforsupport
01010920
SensorType:
TemperatureEvent
Severity:Critical
Description:Upper
Critical-GoingHigh-
Asserted
Inlettemperatureis
toohigh
1.Checkambienttemperatureiswithin
environmentspec.2.ChecktheLenovo
supportwebsiteforanapplicabletipor
firmwareupdatethatappliestothiserror.3.
CheckFanstatus.ifFanisbroken,please
replacethenewFan.4.ContactyourLenovo
servicerepresentativeforsupport
01010720
Inlet_Temp
SensorType:
TemperatureEvent
Severity:Warning
Description:Upper
Non-Critical-GoingHigh
-Asserted
Inlettemperatureis
toohigh
1.Checkambienttemperatureiswithin
environmentspec.2.ChecktheLenovo
supportwebsiteforanapplicabletipor
firmwareupdatethatappliestothiserror.3.
CheckFanstatus.ifFanisbroken,please
replacethenewFan.4.ContactyourLenovo
servicerepresentativeforsupport
AppendixA.TMMerrormessages155