EasyManua.ls Logo

Lenovo ThinkServer sd350 - Appendix B. Diagnostic Error Messages

Lenovo ThinkServer sd350
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AppendixB.Diagnosticerrormessages
Usethisinformationtoresolveanyissuesthatwerefound.
MessageDescriptionAction
MemoryTestFailedMemoryFailurewasdetected.
1.PleasecheckECCanderror
logsinsetup,testreportsand
verifyECCindicatorsonsystem
boardtoidentifyfailingmodule.
ECCcircuitrymayhaverecovered
thefailingmoduleandfurtherdata
isincludedinthereportunder
criticalerrorlogsforverification
test.
2.Reseatfirstly.Ifitstillfails,then,
replacedefectivemoduleand
contactLenovoCustomerService
forfurthersupportoptions.
MegaRaidTestFailedRaidcontrollertesthasdetected
anerror.
1.Pleaserefertodrivestatusin
thetestresultstoseeifRAID
drivesareresponding.Ifno
response,checkinstalleddrivers
toseeifactive.Ifdrivedegraded,
oneoftheraiddriveshasfailed
andneedstobereplaced.
2.Makesurealldrivecarriers
areinplaceandlockedposition.
MakesureRAIDBIOSsettings
areproperlyset.
3.Replacearaidcard.
4.Ifstillfails,pleasecontact
LenovoCustomerServicefor
furtheroptions.
LSITestFailed
Raidcontrollertesthasdetected
anerror.
1.Pleaserefertodrivestatusin
thetestresultstoseeifRAID
drivesareresponding.Ifno
response,checkinstalleddrivers
toseeifactive.Ifdrivedegraded,
oneoftheraiddriveshasfailed
andneedstobereplaced.
2.Makesurealldrivecarriers
areinplaceandlockedposition.
MakesureRAIDBIOSsettings
areproperlyset.
3.Replacearaidcard.
4.Ifstillfails,pleasecontact
LenovoCustomerServicefor
furtheroptions.
©CopyrightLenovo
169

Table of Contents

Other manuals for Lenovo ThinkServer sd350

Related product manuals