AppendixB.Diagnosticerrormessages
Usethisinformationtoresolveanyissuesthatwerefound.
MessageDescriptionAction
MemoryTestFailedMemoryFailurewasdetected.
1.PleasecheckECCanderror
logsinsetup,testreportsand
verifyECCindicatorsonsystem
boardtoidentifyfailingmodule.
ECCcircuitrymayhaverecovered
thefailingmoduleandfurtherdata
isincludedinthereportunder
criticalerrorlogsforverification
test.
2.Reseatfirstly.Ifitstillfails,then,
replacedefectivemoduleand
contactLenovoCustomerService
forfurthersupportoptions.
MegaRaidTestFailedRaidcontrollertesthasdetected
anerror.
1.Pleaserefertodrivestatusin
thetestresultstoseeifRAID
drivesareresponding.Ifno
response,checkinstalleddrivers
toseeifactive.Ifdrivedegraded,
oneoftheraiddriveshasfailed
andneedstobereplaced.
2.Makesurealldrivecarriers
areinplaceandlockedposition.
MakesureRAIDBIOSsettings
areproperlyset.
3.Replacearaidcard.
4.Ifstillfails,pleasecontact
LenovoCustomerServicefor
furtheroptions.
LSITestFailed
Raidcontrollertesthasdetected
anerror.
1.Pleaserefertodrivestatusin
thetestresultstoseeifRAID
drivesareresponding.Ifno
response,checkinstalleddrivers
toseeifactive.Ifdrivedegraded,
oneoftheraiddriveshasfailed
andneedstobereplaced.
2.Makesurealldrivecarriers
areinplaceandlockedposition.
MakesureRAIDBIOSsettings
areproperlyset.
3.Replacearaidcard.
4.Ifstillfails,pleasecontact
LenovoCustomerServicefor
furtheroptions.
©CopyrightLenovo