0B010796
SensorType:Other
Units-basedsensor
EventSeverity:Warning
Description:Upper
Non-Critical-GoingHigh
-Asserted
Nodeoutputpower
istoohigh
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
0B010B9A
SensorType:Other
Units-basedsensor
EventSeverity:Critical
Description:Upper
Non-Recoverable-Going
High-Asserted
CPUpower
consumptionis
toohigh
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
0B01099A
CPU_Power
SensorType:Other
Units-basedsensor
EventSeverity:Critical
Description:Upper
Critical-GoingHigh-
Asserted
CPUpower
consumptionis
toohigh
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
0B010B9B
SensorType:Other
Units-basedsensor
EventSeverity:Critical
Description:Upper
Non-Recoverable-Going
High-Asserted
Memorypower
consumptionistoo
high
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
0B01099B
Memory_Power
SensorType:Other
Units-basedsensor
EventSeverity:Critical
Description:Upper
Critical-GoingHigh-
Asserted
Memorypower
consumptionistoo
high
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
086F06A0
PSU_Mismatch
SensorType:Power
SupplyEventSeverity:
CriticalDescription:
ConfigurationError-
Asserted
Therearedifferent
capacityorvoltage
ofPSUsthatare
pluggedinchassis.
1.See“Replacingahot-swappowersupply”
onpage99
tocheckifPSUsofdifferent
voltageareinstalled2.ChecktheLenovo
supportwebsiteforanapplicabletipor
firmwareupdatethatappliestothiserror.3.
Restarttheserver.4.Suggesttousethe
sametypeofPSUs.5.ContactyourLenovo
servicerepresentativeforsupport
086F01A1
086F01A2
SensorType:Power
SupplyEventSeverity:
CriticalDescription:
PowerSupplyFailure
Detected-Asserted
PSUisOCPorOVP
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport
086F03A1
086F03A2
PSU%_Status(%=
PSUnumber)
SensorType:Power
SupplyEventSeverity:
CriticalDescription:
PowerSupplyInputLost
(AC/DC)-Asserted
AClost
1.ChecktheLenovosupportwebsiteforan
applicabletiporfirmwareupdatethatapplies
tothiserror.2.ContactyourLenovoservice
representativeforsupport